Roschcrete Technologies  ·  Punjab, India Baffle range products  ·  Made in India
RUFICSRoschcrete Technologies

RUFICS panel · rubber fiber reinforced polyurethane The round never leaves the range

That is the entire job of a sacrificial lining, and it is the reason a baffle range can sit inside an installation instead of out in open country. RUFICS is a composite lining developed for the lower stretch of a baffle wall: rubber fiber reinforced polyurethane with composite steel, light enough to bolt to an existing RCC beam.

Section through a baffle wall with RUFICS sacrificial lining along its lower portion, absorbing an incoming round BAFFLE WALL RUFICS LINING ROUND GROUND LEVEL
Panel weight
<200 KG/M²
Test regime
TBRL BR MANUAL
Function
Anti-ricochet SACRIFICIAL
Panel size
500 × 500 MM

Danger area · stage 01 of 05

A range takes up less land than the land it needs

An open range is not just the firing point and the targets. It is the whole danger area behind them, which has to stay clear of everything. Scroll, and watch what each part of a baffle range takes off that area.

Plan of a firing range: the danger area shrinks as side walls, overhead baffles, ground barriers and sacrificial lining are added, until it is contained inside the installation perimeter GRID REF 04 SECTOR B ADJACENT LAND FIRING POINT SIDE WALLS GROUND BARRIERS SACRIFICIAL LINING STOP BUTT
Schematic · extent indicative, not to scale Danger area shown in red
STAGE 01

An open range needs the land behind it

Nothing stops a round except distance. The danger area runs far past the targets and spreads wide on either side, and every metre of it has to be kept clear of people, roads and buildings. That is why ranges end up far from the units that need them.

NO CONTAINMENT · OPEN RANGE
STAGE 02

Side walls take the width away

Walls down both flanks stop a round that leaves the lane sideways. The danger area stops spreading outward and starts to follow the shape of the range itself.

SIDE WALLS · STRUCTURE
STAGE 03

Overhead baffles take the distance away

Baffle walls hang across the range so a round fired high meets structure instead of sky. Without a path upward, the danger area stops reaching out beyond the stop butt.

BAFFLE WALLS · ARMOUR PLATE
STAGE 04

Ground barriers take the skip away

A low round striking the range floor can travel a long way. Box barriers set between the lanes catch it where it lands, closing the last route out.

GROUND BARRIER · RUSTER
STAGE 05

Lining keeps it that way

Structure only contains a round if it survives being hit, thousands of times, in the same band along the bottom of every wall. Sacrificial lining absorbs those strikes instead of returning them, and is replaced when it is consumed. This is where RUFICS works.

RUFICS · SACRIFICIAL LINING

The range no longer needs the land around it.

Firing range products

Four families, supplied for the whole range

Every part of that sequence is something we make. Most clients come for one and specify the rest once they see how the range behaves.

01

Armour plate

High-hardness plate facing baffle walls and the target gallery, where direct strikes concentrate.

02

Sacrificial lining

SIFCON, FICS and RUFICS panels for the lower stretch of baffle walls — the layer meant to be consumed.

03

Ground barrier / RUSTER

Box barriers along the range floor that trap mis-fired rounds before they travel.

04

Target systems

Manual or motorised target frames built to the user's own range specification.

The panel

RUFICS, in plain terms

Rubber fiber reinforced polyurethane with composite steel, built for the lower stretch of a baffle wall. Same position as a concrete-based lining, same test regime, less weight hanging off the beam.

Elevation of a RUFICS panel showing its 500 by 500 millimetre face, steel perimeter frame, capped corner fixings and 80 to 115 millimetre thickness 500 mm 500 THICKNESS 80–115 mm · STEEL FRAME · CAPPED FIXINGS
Standard panelELEVATION · INDICATIVE
Standard size
500 × 500 mm
Thickness
80 – 115 mm
Weight
< 200 kg / m²
Material class
Rubber fiber reinforced PU + composite steel
Function
Sacrificial, anti-ricochet
Position
Lower baffle wall
Fixing
Bolted to RCC beam fixings
Test regime
TBRL BR manual 2014 / 2020
Protection target
NIJ Level III class
Fire behaviour
Class A target, self-extinguishing
Origin
Made in India

Weight is not a spec line. It is the whole install.

Every kilogram has to be carried up a wall, held while it is aligned, and hung off fixings drilled into a beam that is already holding the wall up. Bringing the panel under 200 kg per square metre changes the anchor schedule, the lifting gear and how many people have to be on site to put one run up.

It changes the end of the panel's life too. A sacrificial layer is meant to be consumed and swapped — the lighter it is, the less a range has to shut down to do it.

Released on request

The rest of the file

Detailed engineering goes to identified buyers after an enquiry, under the project's own confidentiality terms.

Request the datasheet
  • Full layer build-up and bonding system
  • Test reports and reference letters
  • Fixing drawings and anchor schedule
  • Comparative data against concrete lining
  • Project references and site contacts
  • Replacement and maintenance schedule

Figures describe the design specification. Protection, durability and fire performance are confirmed by testing at an approved laboratory for each project and its stated threat level.

Choosing a lining

Concrete or rubber: choosing a lining

SIFCON and FICS concrete panels are the proven, lower-cost choice for most ranges. RUFICS is the lighter option where the structure cannot carry the weight.

Criterion SIFCON / FICSConcrete-based Recommended RUFICSRubber composite
Price (indicative) ₹18,000 – 24,000 per m² ₹28,000 – 32,000 per m²
Ballistic protection TBRL BR manual 2014 / 2020 TBRL BR manual 2014 / 2020
Anti-ricochet behaviour Specified and tested as anti-ricochet Rubber matrix absorbs rather than returns
Field record Long service history in Indian ranges Newer alternative, anti-corrosion coated
Material family High-grade concrete with composite fibers Rubber fiber reinforced PU with composite steel
Panel weight Heavier per square metre Under 200 kg/m²
Best for New ranges and most retrofits Structures with strict weight limits

Prices are indicative, excluding GST, and depend on specification, thickness, quantity and site. Final price on quotation. We supply both.

Installation control

The lining is only as good as the way it is hung

A panel that is correct on paper and badly fixed is a liability on a live range. These are the controls we apply on every installation.

CONTROL 01

Laser marking

Hole positions marked with a laser rather than measured by hand, so alignment holds across a long wall.

CONTROL 02

Rebar scanning before drilling

Reinforcement located before a single hole is made, which avoids repeat drilling and protects the beam.

CONTROL 03

Laser levelling

Panel lines set with a laser, keeping the gap between panels to a minimum and the face flat.

CONTROL 04

Fixing protection

Hardwood batten at the rear and a wooden cap at the front shield the nuts and bolts from direct strike.

How we work

From first message to a range back in use

  1. 01

    Survey

    We measure the range as it actually is, and check what the structure can carry before anything is specified.

  2. 02

    Specification

    Lining selected against your threat level and the standard you work to, with the datasheet released to you.

  3. 03

    Manufacture

    Panels produced at our works in Punjab under process control, with sample testing before bulk production.

  4. 04

    Installation

    Rebar scanned, holes laser-marked, panel lines laser levelled, fixings capped and protected.

  5. 05

    Handover

    Inspection of the finished run before the range is used, with documentation for your records.

Plan of a lined kill house: a fixed outer shell with movable interior partitions and lining on every surface ROOM 1 ROOM 2 ROOM 3 LINING ON EVERY SURFACE

Kill house lining

Same problem, four walls closer

A kill house is a baffle range folded into a room. The distances collapse, the angles get worse, and the people are inside it rather than behind it. Every surface becomes a target and every hard face becomes a ricochet risk.

  • Anti-ricochet rubber lining on walls and floor
  • Movable partitions so the layout follows the syllabus
  • Fragment collection at the base of every panel
  • Acoustic treatment specified alongside the ballistic layer
Kill house lining →

Testing & approvals

How the panel is proven

Built to the BR manual

Construction follows the TBRL Ballistic Resistance manual, so what is supplied matches what the range was specified against.

Tested to manual criteria

Testing criteria follow the same manual, in its 2014 and 2020 norms, rather than an in-house standard of our own.

Any approved government lab

Ballistic approval can be carried out at any suitable government laboratory the client nominates.

Test scope and results are specific to the sample, threat level and conditions of each test. Reports are shared with identified buyers on request.

Questions

What buyers usually ask first

What does RUFICS stand for?

Rubber Fiber Reinforced Polyurethane with Composite Steel. It describes a material class rather than a single fixed recipe, and the panel is supplied against the specification agreed for your range.

How is RUFICS different from SIFCON and FICS panels?

All three do the same job — sacrificial lining on baffle walls — from different material families. SIFCON and FICS are high-grade concrete composites. RUFICS is the rubber and polyurethane alternative, developed to bring the weight down. Which suits your range depends on the specification, the structure and the threat level.

Where exactly does the lining go on a baffle wall?

Along the lower stretch of the wall, where rounds concentrate. The rest of the wall is not subjected to the same repeated strike, so lining the full height is rarely specified.

Can RUFICS be retrofitted to an existing range?

Yes. It is bolted to fixings taken into the existing RCC beam, and the lower weight is specifically what makes retrofitting practical. We scan the beam before drilling.

Is the panel replaceable once it is consumed?

That is the intention — a sacrificial layer is meant to be consumed and swapped rather than repaired in place. Panels come off their fixings, which is why the bolt heads are protected during installation.

Will you share the full technical details?

The full datasheet, test reports and fixing drawings go to identified buyers after an enquiry. Send your range details and we will tell you what applies to your project.

Do you supply the rest of the range as well?

Yes — armour plate, ground barriers and target systems alongside the lining. Most ranges need more than one of them.

Enquiry

Tell us about the range

Wall lengths, the threat level you are specified against, and whether the range is new or being retrofitted. That is enough for us to come back with something useful.

Location Roschcrete Technologies Private Limited
Punjab, India Direct WhatsApp +91 82830 47770
+91 82830 47770
info@roschcrete.com Follow

Opens WhatsApp with your enquiry filled in.

Chat on WhatsApp